Electronic Pressure Sensor, 5075 psi

  • Ifm
  • Electronic Pressure Sensor, Range -14.5 to 362 psi, Analog Output 4 to 20mA or 0 to 10V DC, Control Output PNP, Programmable On/Off Setting, Power Required 18 to 30V DC, Process Connection 1/4 in NPT, Electrical Connection 4 Pin M12, Display 4 Digit LED, Wetted Materials Stainless Steel, Housing Material Stainless Steel, Operating Temp. Range -13 Degrees to 176 Degrees F, IP Rating 65/67, Max. Pressure 5,075 psi, Standards CE, CULus

    graingerSKU: 52PG33, mscSKU: , zoro_no: G5892979, mongo_id: 65bbe74d3aaddbd5a90873f8

Web Price
$632.49 / each

Product Details

-25...80
4 to 20mA or 0 to 10V DC
4...20; (scalable 1:5)
4...25 bar 58...362.5 psi 0.4...2.5 MPa
-1...20 bar -14.5...290 psi -0.1...2 MPa
0...10; (scalable 1:5)
for industrial applications
<± 0,25 (BFSL) / <± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
IO-Link
Connector: 1 x M12; coding: A; Contacts: gold-plated
PNP
Germany
< 35
0...4
0...4
0...50
4 Digit LED
4 Pin M12
PNP/NPN
DIN EN 61000-6-2 DIN EN 61000-6-3
Stainless Steel
<± 0,1; (Turn down 1:1)
0.05 bar 0.5 psi 0.005 MPa, 0.01 bar 0.1 psi 0.001 MPa
yes
application specific tag
function bit length pressure 14 binary switching information 2, function bit length pressure 16 device status 4 binary switching information 2
0.01
1.1
65/67
<± 0,05; (Turn down 1:1; per 6 months)
stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
stainless steel (1.4404 / 316L); AI2O3 (96%; ceramics); FKM
70 bar 1015 psi 7 MPa
500
5,075 psi
3
2
ceramic-capacitive pressure measuring cell
-1...25 bar -14.5...362.5 psi -0.1...2.5 MPa
liquids and gases
-25...80
350 bar 5075 psi 35 MPa
0.11 bar 1.5 psi 0.011 MPa, 0.15 bar 1.5 psi 0.015 MPa
100; (500 V DC)
2000
100 million
2.3, 3
138
1
2
Number of digital outputs: 2; Number of analogue outputs: 1
Programmable
-13 Degrees to 176 Degrees F
18...30 DC; (to SELV/PELV)
normally open / normally closed; (parameterisable)
switching signal; analogue signal; IO-Link; (configurable)
yes
1
hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output
250
18 to 30V DC
0.3
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
150 bar 2175 psi 15 Mpa
1/4 in NPT
Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000), Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
IP 65; IP 67
III
-14.5 to 362 psi
<± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
A; (when pin 2 not connected: B)
-0.95...24.9 bar -13.5...361 psi -0.095...2.49 MPa, -0.95...24.9 bar -13.7...361.1 psi -0.095...2.49 MPa
< 1.5
no (can be retrofitted)
yes
IEC 61131-9
-0.85...25 bar -12...362.5 psi -0.085...2.5 MPa, -0.84...25 bar -12.2...362.6 psi -0.084...2.5 MPa
DIN EN 60068-2-27 50 g (11 ms)
yes
yes
Gold-plated contacts
CE, CULus
-40...100
<± 0,4; (Turn down 1:1)
< 500
<± 0,2; (-0...80°C)
<± 0,2; (-0...80°C)
> 50; (depends on lubrication, seal and pressure rating)
2
COM2 (38,4 kBaud)
relative pressure; vacuum
pulsed
UL Approval no. J012
-1000
DIN EN 60068-2-6 20 g (10...2000 Hz)
Stainless Steel