Phase Ctrl Relay, 380-480VAC In 8A, Dpdt

  • Schneider Electric
  • Phase Control Relay, Contact Form DPDT, Contact Rating (AC) 8 A @ 250V, Contact Rating (DC) 0.01 A @ 5V, Current Rating 8 A, Flat Pin Width Not Applicable, Input Voltage 380 to 480V AC, Monitored Parameters Overvoltage, Phase Failure, Phase Sequence, Number of Pins 9, Restart Auto, Restart Time Delay 1.5 sec, IP Rating IP40, Mounting Style DIN Rail, Body Depth 3.13 in, Body Height 3.54 in, Body Width 0.89 in, Electrical Operating Durability 100,000, Frequency 50/60 Hz, Housing Material Plastic

    graingerSKU: 69ZP30, mscSKU: , zoro_no: G7122864, mongo_id: 65bbe7649a749db822734827

Web Price
$201.24 / each
Qty

Product Details

8 A @ 250 V
-20-50°C 60 Hz || -20-60°C 50 Hz AC/DC
-40-70°C
3.13 in
3.15 in
3.54 in
3.54 in
0.89 in
0.9 in
screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
DPDT
DPDT
8 A @ 250V
0.01 A @ 5V
cadmium free
2 C/O
20 % + 20 % Un
Solid
Multiple
8 A
0.01 A @ 5V
2.5 kV AC 50 Hz, 1 min IEC 60255-27
Terminal Strip
Screw
100000 cycles
100,000
immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22
Not Applicable
50/60 Hz
Plastic
2-2 % fixed selectable
10 ms
200 to 240 V AC
380 to 480V AC
> 100 MOhm 500 V DC IEC 60255-27
IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)
IP40
Current Sensing Relay
150 ms measurement cycle as true rms value
122 Degrees F
1,250 VA
8 A
250V AC
< 1 % over the whole range with voltage variation || < 0.05 %/°C with temperature variation
380...480 V voltage AC
10000000 cycles
30,000,000
-4 Degrees F
10 mA
Overvoltage, Phase Failure, Phase Sequence
Surface
any position
DIN Rail
35 mm DIN rail conforming to EN/IEC 60715
8A
9
2 C/O
3.13 in
III IEC 60664-1 || III UL 508
1
3 phase
3 IEC 60664-1 || 3 UL 508
1,250 VA
15-15 VA 480 V AC 60 Hz
GL || CSA || RCM || CE || EAC || CCC || UL
3-phase control relay
93-97 % 25-55°C IEC 60068-2-30
overvoltage and undervoltage detection || phase sequence || phase failure detection
DIN-Rail
RM22TR
control relay
+/- 0.5 % input and measurement circuit || +/- 3 % time delay
1500 ms at maximum voltage
<= 300 ms
Auto
1.5 sec
650 ms
0.01 to 8.00 A
+/- 10 % of the full scale
0.916666666666667
15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27
DIN-Rail / 9
C-Tick, CSA Certified, EN/IEC 60255-1, EN/IEC 61000-6-4, EU RoHS, GL, GOST, Reach Regulation, UL Listed
LED (Yellow) relay ON || LED (Green) power ON
50...60 Hz +/- 10 %
304-576 V AC
2000 VA
<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
2...20 % of Un selected
0.6-1 N.m IEC 60947-1
<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
0.10 to 30 sec
Adjustable 0.01 to 8.00 A
Relay
AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1
0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
< 100 V AC
380...480 V phase to phase
3.2 oz
22.5 mm
380...480 V AC

Viewed together